Skip to main content

Products & E-shop

3-way shut-off valve with 1 G3/8'' V padlock Pneumatic components

3-way shut-off valve with 1 G3/8'' V padlock

Product N° 050-25
3-way shut-off valve with 1 G3/8'' V padlock Pneumatic components
AIRCOMP
Product in stock
Delivery 24/72h from €15

Helpful information:

TECHNICAL CHARACTERISTICS OF THE BLOCK - FR + L / F + R + L

  • Connection : G 3/8" (available on request in G1/2" : series 052)
  • Flow rate : 1500 Nl/min (P = 6,3 bar - Δp = 1 bar)
  • Used to cut off the air supply and at the same time to discharge the downstream circuit.
    - The blocking device is particularly useful during maintenance operations. It prevents the unauthorized pressurization of the system.
    - Possibility of wall mounting using the holes provided.
    - Discharge connection: 1/4" BSP female thread.
    - Maximum inlet pressure: 12.5 bar = 180 Psi = 1.25 MPa.
    - Temperature range: 5° to 50° C.
    - The device is delivered with a padlock.
    - Reference flow rate (P = 10 bar - Δp = 1 bar) : 2580 Nl/min.
    - Weight : 0,270 Kg.

    Download technical datasheet

  • - Very good condensation separation.
    - Low pressure drop.
    - Provided with holes for wall mounting.
    - Quick attachment of the cup with anti-pull-out safety mechanism.
    - Standard filtration degree of 20 microns (on request 5 microns).
    - Manual and semi-automatic condensate draining device in the standard integrated (SS) or automatic float (SA) version.
    - Polyamide bucket with reinforced resistance and external protection.
    - Quantity of condensation recovered: 42 cm3.
    - Maximum operating pressure: 12.5 bar = 180 Psi = 1.25 MPa.
    - Temperature range: 5 to 50°C (41 to 122°F).
    - Reference flow rate (P = 10 bar - Δp = 1 bar) : 2500 Nl/min.
    - Weight : 0,225 Kg.

    Download technical datasheet

  • - Rolling diaphragm.
    - Stability of the regulated pressure, even if the upstream pressure varies.
    - High flow rate with low pressure drop.
    - Rapid elimination of excess pressure downstream.
    - Provided with holes for wall or bracket mounting.
    - Knob with regulation locking device.
    - Built-in automatic pressure relief.
    - Pressure gauge connection: 1/8" BSP female thread.
    - Adjustment range: 0 ÷ 4 bar, 0 ÷ 8 bar (standard), 0 ÷ 12,5 bar .
    - Maximum inlet pressure: 12,5 bar = 230 Psi = 1,60 MPa.
    - Temperature range: from 5° to 50° C.
    - Reference flow rate (P = 6,3 bar - Δp = 1 bar) : 2100 Nl/min.
    - Weight : 0,325 Kg.

    Download technical datasheet

  • - Rolling diaphragm.
    - Stability of the regulated pressure, even if the upstream pressure varies.
    - High flow rate with low pressure drop.
    - Rapid elimination of excess pressure downstream.
    - Provided with holes for wall or bracket mounting.
    - Knob with regulation locking device.
    - Built-in automatic pressure relief.
    - Pressure gauge connection: 1/8" BSP female thread.
    - Adjustment range: 0 ÷ 4 bar, 0 ÷ 8 bar (standard), 0 ÷ 12,5 bar.
    - Very good condensation separation.
    - Quick coupling of the bucket with anti-extraction safety mechanism.
    - Other functional characteristics as for the standard filter.
    - Reference flow rate (P = 6,3 bar - Δp = 1 bar): 2100 Nl/min.
    - Weight: 0,410 Kg.

    Download technical datasheet

  • Device allowing to cut off the power supply and at the same time to unload the downstream circuit by means of a remotely operated electro-pneumatic control (NF).
    - Available with CNOMO (standard) or MICROSOL control.
    - Electrical voltage: 24V DC (standard), 24V AC or 220V AC.
    - Available with pneumatic control on request.
    - Possibility of wall mounting using the holes provided.
    - Connection for discharge: 1/4" BSP female thread.
    - Minimum allowable pressure: 3 bar = 40 Psi = 0.3 MPa.
    - Maximum working pressure: 10 bar = 145 Psi = 1 MPa.
    - Temperature range: 5° to 50° C.
    - Reference flow rate (P = 10 bar - Δp = 1 bar) : 2580 Nl/min.
    - Weight : 0,280 Kg.

    Download technical datasheet

  • Gradual pressurization of the system up to operating pressure.
    - Before the maximum available pressure is released, air is slowly introduced into the downstream circuit until 60% of the upstream pressure is reached.
    - To adjust the pressurization time, use the built-in flow regulator.
    - Provided with holes for wall mounting.
    - Minimum allowable pressure: 3 bar = 40 Psi = 0.3 MPa.
    - Maximum working pressure: 10 bar = 145 Psi = 1 MPa.
    - Temperature range: 5 to 50°C (41 to 122°F).
    - Reference flow rate (P = 10 bar - Δp = 1 bar) : 2580 Nl/min.
    - Weight : 0,270 Kg.

    Download technical datasheet

  • Proportional oil mist type.
    - Constant lubrication over time.
    - Guaranteed operation even at low flow rates.
    - Fine adjustment of the quantity of lubricant.
    - 360° drip display.
    - Oil filling plug.
    - Quick attachment of the bucket with anti-pull-out safety mechanism.
    - Provided with holes for wall mounting.
    - Polyamide bucket with reinforced resistance, with external protection, capacity 68 cm3.
    - Recommended oil viscosity: ISO VG32.
    - Maximum working pressure : 12,5 bar = 180 Psi = 1,25 MPa.
    - Temperature range: 5° to 50° C (41° to 122° F).
    - Reference flow rate (P = 10 bar - Δp = 1 bar) : 2060 Nl/min.
    - Weight : 0,230 Kg.

    Download technical datasheet

  • Indispensable when you want to load the oil quickly and safely without interrupting the normal operation of the system.
    - Filling is controlled by holding down the button on the base of the grease gun body.
    This causes a vacuum inside the bowl, which allows the oil to be sucked in.
    - The flow stops only when the button is released.
    - The oil level must be checked visually.
    - Minimum activation pressure: 3 bar = 40 Psi = 0.3 MPa.
    - Other functional characteristics as for the standard model.
    - Reference flow rate (P = 10 bar - Δp = 1 bar) : 2060 Nl/min.
    - Weight : 0,270 Kg.

    Download technical datasheet

3D CAD File

To download the 3D CAD file (.step) of the articles you must log in to your account or register. If you are logged in and you are still reading this message, then the 3D is not directly available for download, thank you for contacting us.

Recently viewed

Save
Cookies user preferences
We use cookies to ensure you to get the best experience on our website. If you decline the use of cookies, this website may not function as expected.
Accept all
Continue without accepting
Read more
Analytics
Tools used to analyze the data to measure the effectiveness of a website and to understand how it works.
Google analytics
Accept
Decline
Google Analytics
Accept
Decline
Marketing
Set of techniques which have for object the commercial strategy and in particular the market study.
Google
Accept
Decline
Unknown
Unknown
Accept
Decline